<LOGO>
FM Transmitter Measurement Report
Created: 2024-12-08 12-18-30
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
107.80 MHz 5/5, 54 dBuV P2 SR
Pilot RDS Phase Difference
7.3 kHz 5.6 kHz 0 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
15 kHz 17 kHz 19000 0,0053
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
-5,4 dBr -3,13 dBr -1,2 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"P2 SR " E402 14 (Classics) 0 1 1 9 11:18, 8.12.2024
RT
"Text & musik med Eric Schüldt hltemperierte Klavier: Del 1, Prel"
AF EON
90.7, 91.7, 93.6, 94.5, 94.7, 97.5 MHz E201, E203, E224, 5032
FM Scope Max at: 17 kHz MIN: 15 kHz % above 76 kHz: 0,0053 Acquired: 2024/12/08 12.17.26 Total samples: 19000 Equivalent time: 0:15:50 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: -1,2 dBr MIN: -5,4 dBr AVE: -3,13 dBr % above 12,2 dBr: 0,0 Last value: -3,8 dBr (2024/12/08 12.17.26) 12.04 12.06 12.08 12.10 12.12 12.14 12.16 0 50 100 Dev. MAX [kHz] -6 -4 -2 0 Pm [dBr]